Skip to Content To homepage

Versa 20×2/Cary5000

Versatile dual temperature control for the Cary 4000, 5000, 6000i and 7000 UV-Vis-NIR Spectrophotometers
Product Overview

The Versa 20×2/Cary5000 combines two Versa 20 cuvette holders for use in the dual-beam Cary 4000, 5000, or 6000i UV-Vis-NIR Spectrophotometers. It provides independent Peltier temperature control for both the sample and reference cuvettes. Use the Versa 20/Cary5000 in the biological range of 0 °C to 105 °C, or non-aqueous samples, purchase the extended temperature option and run the Versa 20×2/Cary5000 up to 150 °C. Add a Windowed Jacket, purge with dry gas and run the temperature to well below zero. If necessary, run the sample and reference cuvettes at different temperatures. The mounted Versa 20/Cary5000 replaces both the sample and reference cuvette holders normally provided with the spectrophotometer. Utilities are brought out of the sample compartment using an access plate that mounts below the Agilent extended “nose” assembly. Operate the TC 1/Single Temperature Controller using the menu button or control via program T-App. Use an ADL program for temperature ramping with WinUV ADL Shell software.

Product Features

Temperature control for both sample and reference
Optional extended temperature range
Variable speed magnetic stirring
Dry gas purge for work at low temperature
Bases and posts for mounting in the spectrophotometer
Cuvette lifters for removal of cuvettes
Probe input for sample temperature
NIST-traceable temperature calibration
ADL program for temperature ramping

  • Technical Specifications
    Number of cuvettes controlled
    2
    Typical use
    Absorbance (sample and reference)
    Standard cuvette size (outside)
    12.5 mm x 12.5 mm
    Optical ports per cuvette
    2
    Optical port dimensions
    10 mm high x 10 mm wide
    Cuvette z-height
    8.5 or 15 mm for most models
    Windowed jacket available
    2 windows
    Normal factory set temperature range
    -40 °C to +105 °C
    Temperature range easily achievable
    -15 °C to +105 °C
    Range with special techniques
    -40 °C to +105 °C
    Extended factory set temperature range
    -55 °C to +150 °C
    Extended temperature range achievable
    -50 °C to +150 °C
    Temperature precision
    ±0.02 °C
    Temperature accuracy
    Better than ±0.15 °C from 0 ⁰C to +80 ⁰C
    Accuracy greater range
    Better than ±0.3 ⁰C from ‐20 ⁰C to +110 ⁰C
    Temperature reproducibility
    Better than ±0.07 °C
    Thermistor probes accepted
    Series 400 or Series 500
    Magnetic stirring motor type
    Stepper
    Magnetic stirring speed range
    1-2500 rpm
    Default stirring speed
    1200 rpm
    Stirring speed best performance
    60-1800 rpm
  • Basic Package

    Versa 20×2 – Pair of temperature-controlled cuvette holders (standard z-height = 15 mm)
    TC 1/Dual – Temperature Controller
    Base plate and utility access panel
    BATH 10 – Circulator
    NIST-traceable calibration and performance data
    ADL program for temperature ramping
    Accessories – Magnetic stir bar, tubing, cables and two opaque caps

  • Accessories